L – LIBS

Innovative Real-Time In-Situ Liquid Contamination Measurement Equipment
L-LIBS, Liquid-Laser Induced Breakdown Spectroscopy

OVERVIEW

Innovative Real-Time In-Situ
Liquid Contamination Measurement Equipment

L-LIBS (Liquid-Laser Induced Breakdown Spectroscopy)

Industry 4.0 is the current trend of economy and market need for Environmental management and regulatory pressures to corporations is increasing dramatically.

 

Water, air and soil contamination is severe in various areas, such as shale gas extraction sites, abandoned mines, drinking water and air near industrial complex, cities etc.

 

To correspond market needs for environment management, it is essential to prevent for large-scale contamination. However until now it is difficult to analyze source of pollutant in real time, especially in the water and air.

 

For existing element analyzing equipment and methods, it takes 3 to 5 days to complete every processes including pre-treatment, sampling etc.

 

L-LIBS(patented) is revolutionary, portable, high performance inlet-outlet LIBS analyzer for real-time water quality analysis/monitoring. With L-LIBS, it is possible to faster decision making on contaminated areas.

Real-Time Monitoring of Liquid Contamination

L-LIBS

l-libs-machine

Specification

null

Liquid Contaminants

Quantitative
&
Qualitative Analysis

null

Real-Time


Conventional measurements Require 2~3days

null

Smart


Mobile App. monitoring / Big Data & Deep Learning Analysis

null

One Shot, All Kill


Measure all contaminant elements at onceAs accurate as expensive ICP

null

Portable for In-situ test


Only 25kg in total weight

COMPARISON TO EXISTING EQUIPMENT

 AASICPL-LIBS
PretreatmentAcid elution
Filters filtration
+ Chemical waste
Acid elution
Filters filtration
+ Chemical waste
No-pretreatment
(Include filter)
No chemical waste
Equipment OperationSkilled professionalsSkilled professionalsEasy to operate
Total analysis time3 to 4 days3 to 4 daysReal-time
(within 10 minutes)
MobilityDisable
Lab analysis
Disable
Lab analysis
Enable
Field analysis
Analytical resultsOn-site checkOn-site checkOn-line check
(Web site)
SensitivityHigh
(R2: >0.999)
High
(R2: >0.999)
Relatively high
(R2: >0.9)
Sample injectionInjection by peopleInjection by peopleAutomatic injection by injection pump
Analysis type(Mainly)
qualitative analysis
(Precise)
quantitative analysis
Qualitative and quantitative analysis (Contamination analysis)
Operating cost
(including consumables)
35 USD/element in a sample20 USD/element in a sample30 USD/all element in a sample

PATENTS & TRADEMARK, PROGRAM REGISTRATION

Real-Time Monitoring of Liquid Contamination

L-LIBS

l-libs-machine